WLAN-Status 26.04.2024 11:07:12
Access Points mit 1 bis 10 Sessions innerhalb der vergangenen 24 Stunden
Berlin-Mitte > Dorotheenstr. 26, Bibliothekswissenschaften
Name: AP-Doro26-R421 Hardware: AP3805i Serial Number: 16381774085M0000 Uptime: 05:16:04 h Last succ. Poll: 26.04.2024 11:04:19 Basic PwrUsage: 4000mW SavedEnergy: 16.265,42 Wh (since: 24.08.2022 23:14:01) IP: 172.19.182.220 eth0: d8:84:66:75:08:bc SW Version: 09.21.20.0001 Home-Controller: UdL6 Active/Backup-Ctrl: UdL6 / GZ Poll-Timeout: 5s R1 5.0 GHzCh: 52+1 (5260 MHz) Pwr-Lvl (5 ≤ 17): 15 dBm Radio-Type: IEEE 802.11ac W.: 40 MHz Max-W: 40 MHz Bond.: Yes Ch-Plan: All Channels DCS: active DCS Threshold: -80 dBm Ch Busy Ø: 2% Rx Frames Ø: 2% AP Tx Ø: 0% MBR: 6 MBit/s Avg Noise: -88dBm Beacon Interval: 100ms R2 2.4 GHzCh: 13 (2472 MHz) Pwr-Lvl (5 ≤ 15): 15 dBm Radio-Type: IEEE 802.11gn W.: 20 MHz Max-W: 20 MHz Bond.: No Ch-Plan: 4-Channel Plan DCS: active DCS Threshold: -80 dBm Ch Busy Ø: 16% Rx Frames Ø: 15% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -90dBm Beacon Interval: 100ms WLAN-Sessions: 3 (R2: 3) Accs: HU: 2 2.4n: 3 valid/invalid/unknown IPs: 3 / 0 / 0 auth/not auth Clients: 3 / - Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 7 / 14 / 30 |
| ||||||||||||||||||||||||
Location: Berlin-Mitte > Dorotheenstr. 26, Bibliothekswissenschaften IGNORE_ZERO_TX_ON_A Required VNS assignment: A:eduroamExternUni3b B:eduroamExternUni3b | |||||||||||||||||||||||||
Name: AP-Doro26-R113 Hardware: AP310i Serial Number: 2035Y-1473600000 Uptime: 20:35:37 h Last succ. Poll: 26.04.2024 11:04:19 Basic PwrUsage: 5800mW SavedEnergy: 15.057,31 Wh (since: 24.08.2022 23:14:01) IP: 172.19.182.196 eth0: 20:9e:f7:76:c7:47 eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 Active/Backup-Ctrl: ECA-UdL6 / ECA-GZ Poll-Timeout: 3s R1 5.0 GHzCh: 44 (5220 MHz) Pwr-Lvl : 10 dBm Radio-Type: IEEE 802.11ax W.: 40 MHz Max-W: 40 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 6% Rx Frames Ø: 3% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -88dBm Beacon Interval: 100ms R2 2.4 GHzCh: 13 (2472 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 16% Rx Frames Ø: 5% AP Tx Ø: 2% MBR: 6 MBit/s Avg Noise: -96dBm Beacon Interval: 100ms WLAN-Sessions: 3 (R1: 3) Accs: HU: 3 5.0a: 1 | 5.0ac: 1 | 5.0ax: 1 valid/invalid/unknown IPs: 3 / 0 / 0 auth/not auth Clients: 3 / - Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 8 / 8 / 10 |
| ||||||||||||||||||||||||
Location: Berlin-Mitte > Dorotheenstr. 26, Bibliothekswissenschaften IGNORE_ZERO_TX_ON_A Required VNS assignment: A:eduroamExternUni3b B:eduroamExternUni3b | |||||||||||||||||||||||||
Name: AP-Doro26-K17 Hardware: AP310i Serial Number: 2035Y-1480200000 Uptime: 20:38:14 h Last succ. Poll: 26.04.2024 11:04:19 IP: 172.19.182.234 eth0: 20:9e:f7:76:c8:91 eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-GZ Active/Backup-Ctrl: ECA-GZ / ECA-UdL6 Poll-Timeout: 3s R1 5.0 GHzCh: 36 (5180 MHz) Pwr-Lvl : 10 dBm Radio-Type: IEEE 802.11ax W.: 40 MHz Max-W: 40 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 2% Rx Frames Ø: 0% AP Tx Ø: 2% MBR: 6 MBit/s Avg Noise: -87dBm Beacon Interval: 100ms R2 2.4 GHzCh: 5 (2432 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 5% Rx Frames Ø: 1% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -99dBm Beacon Interval: 100ms WLAN-Sessions: 1 (R1: 1) Accs: HU: 1 5.0ax: 1 valid/invalid/unknown IPs: 1 / 0 / 0 auth/not auth Clients: 1 / - Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 6 / 7 / 9 |
| ||||||||||||||||||||||||
Location: Berlin-Mitte > Dorotheenstr. 26, Bibliothekswissenschaften SKIP_WHEN_DOWN / IGNORE_ZERO_TX_ON_A Required VNS assignment: A:eduroamExternUni3b B:eduroamExternUni3b |
Hilfe - Aktualisierungsintervall: 5 Minuten
Version 12.5.2, syj, 02.11.2023
Datenerhebung: 26.04.2024 11:04:01 Erzeugt: 26.04.2024 11:07:12 PID 1521623